Pentair intelliflo display not working.

Just to see if I understand how it works... The pump does not show actual RPM, but if in the RPM mode will let you set a % of max RPM. When connected to an EasyTouch and ScreenLogic, the ScreenLogic display will show actually RPM. ... Pentair Intelliflo VSF - RPM speed. Barkyman; Jul 17, 2023; Pumps, Filters, and Plumbing; …

Pentair intelliflo display not working. Things To Know About Pentair intelliflo display not working.

Brad, So, it would work ok for a pool tech doing a normal maintenance, like cleaning the pump basket, skimmer baskets, or filter cleanings, but it would not work well for a pool tech that is trying to troubleshoot an issue with schedules, or how the system is running.Jan 1, 2021. #1. I just installed a pentair intelliflo vsf pump with my jandy aqualink rev QQ controller. Wired both poles thru the filter pump relay as the jandy manual instructs, connected the rs485 wires (pin 2 yellow, pin 3green) as the online refs instruct. Pump properly displays “display not active”, set the controller to vf pump and ...The pump is just a little over 1 year old so past the warranty. It was installed by a professional pool company. The Pentair Intelliflo 2 VST 1.5 HP pump had been working great then abruptly just stopped after a scheduled program. There is no display at all, there were no warning alarms before it quit working either.Pentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy.com/que...Nov 29, 2021 · Pentair Intellichlor Overview - IC15 IC20 IC30 IC40 IC60. In this video I give an overview of how most saltwater chlorinators work. Fix/replace your saltwate...

the spa jet IntelliFlo VS pump at 3000 RPM. Note: Feature Circuits can also be “Scheduled” to run at a specific time. See “Schedules” for details. Select the pump type: 1.Press Menu then Down button to “SETTINGS”. 2.Press Right button, Down button (IntelliFlo) and Right Button to “Pump #1”. Press Right button 2 times to “Pump ...

Plano, TX. May 4, 2017. #37. Have to say I was fairly skeptical on this fix (my LCD screen on Pentair has been blank for a couple of years) but opted to try it as described in this thread. Pics and details from Rwhite692 were very helpful. Spent $4 for foam weatherstrips at HD and that was pretty much it.The Pentair IntelliFlo variable speed pool pump runs a lot quieter than a single speed pump. One reason for its quietness is its totally enclosed fan-cooled design. This also prevents bugs or water from interfering with the fan. An additional reason for its quiet operation is its permanent magnet motor. It runs at a lower temperature, which ...

Re: Anyone ever have the LCD screen go out on the Intelliflo My display went out the same way. The pump still worked, but the display was unreadable. Pentair replaced the display module as Jason noted without replacing the pump. Mine was replaced at the end of the season last year, and we are just opening now, so we will see how the long it lasts.Pentair 357527Z Swimming-Pool-Pump-Accessories, White. Visit the Pentair Store. 4.0 106 ratings. 50+ bought in past month. -35% $28794. List Price: $439.99. Part Number: 357527Z. Innovative and high-performance parts. Kit Keypad Top Cvr Asy Intelliflo Almd.The light icon should turn green. Then go out and look at the actual light and confirm it is on. If it is on, turn the light off using the light button on the EasyTouch. Then confirm that the ScreenLogic light icon goes off. If this works, it proves that your RS-485 com port is working.Aug 27, 2022 · The light icon should turn green. Then go out and look at the actual light and confirm it is on. If it is on, turn the light off using the light button on the EasyTouch. Then confirm that the ScreenLogic light icon goes off. If this works, it proves that your RS-485 com port is working.

I have the Intelliflo also. I run mine at 1100 rpm for skimming and making chlorine with the SWG. It uses 150 watts at 1100 rpm and works great. Here is how the math works 168 watts x 8 hours run = 1344 watts ÷1000 = 1.344 kWh x 30 days = 40.32 kWh x 10.25c/kWh = $4.13 per month

Pentair Intellichlor Overview - IC15 IC20 IC30 IC40 IC60. In this video I give an overview of how most saltwater chlorinators work. Fix/replace your saltwate...

May 5, 2019. #1. I have a 2015 Pentair Intelliflo VS variable speed pump 011018 in which water got inside the poorly designed display. The pump is still running but on the last programmed low speed only. The display is blank and I can't run or program the pump to any other higher speed. A fix would be to replace the drive 353251 for around $630.Basically the pump can see the EasyTouch but the EasyTouch can't see the pump.. The RS-485 has different circuits.. It sends commands out on one circuit and receives commands on another circuit. We have seen several pump where the send circuit is dead, but the pump's screen still says "Display not active" because the receive circuit is still ...Push menu and scroll down to "Settings" and press "Select". Scroll down to "Intelliflo" and press "Select". Select "Pump 1". Pump Type should be "VS". Scroll down to "Speeds" and press "Select". You should see something like the following, your numbers may be different: RPM 1200 1/8. Circuit.San Diego. Jun 19, 2017. #5. Pressing the "Start/Stop" button with the pump running should stop the pump. If you then press the "Start/Stop" button again, that puts the pump in schedule mode. The word "Schedule" should appear on the screen, telling you it's ready to run the schedules that you've programmed into it.Still have questions on your Pentair IntelliFlo? Our customer service team is here to help you.Call: 1.800.831.7133. Find the support you need to connect your water devices to the Pentair Home and Pentair Pro apps. Pentair has FAQs and documentation to get you started. With over 200,000 members, TFP is the largest and most influential pool & spa website on the Internet. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. It is being practiced by thousands of pool owners just like you.

About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Sep 10, 2023 · Understanding The Pentair Intelliflo Display Issue. Having trouble with your pentair intelliflo display? Discover solutions to the pentair intelliflo display issue and get your display working properly in no time. If you’re facing issues with your pentair intelliflo display, it can be frustrating and inconvenient. Nov 29, 2021 · Pentair Intellichlor Overview - IC15 IC20 IC30 IC40 IC60. In this video I give an overview of how most saltwater chlorinators work. Fix/replace your saltwate... #1 I have a 3 year old Pentair Easy Touch control system that is connected to my Pentair 4 speed pump. While trying to get my controller to talk to my remote I erased the EPROM to reset it (it still doesn't communicate, but that is another problem).Pentair Intelliflo Display Not Working Identifying Pentair Intelliflo Display Problems. Taking care of a pool precisely and efficiently is super important. Potential Causes of Pentair Intelliflo Display Not Working. Display issues can stem from a variety of sources, each of... DIY Troubleshooting ...

Solution: Inspect the display module for damage or lose connections. Replace the display module if needed. Communication Error Incorrect communication settings or configurations can cause the display to remain inactive. Check the communication protocol and settings to ensure proper configuration. Solution:The Pentair IntelliFlo variable speed pool pump runs a lot quieter than a single speed pump. One reason for its quietness is its totally enclosed fan-cooled design. This also prevents bugs or water from interfering with the fan. An additional reason for its quiet operation is its permanent magnet motor. It runs at a lower temperature, which ...

I have Pentair Intelliflo VSF pump with a 33000 gallon pool. ... Correct, When the service mode is on, I can change the settings at the actual pump. When the Auto mode is on, it says Display not Active. I understand this. ... The only way to really have my family member getting his pool working a predictable way is for me to understand how …Still have questions on your Pentair IntelliFlo? Our customer service team is here to help you.Call: 1.800.831.7133. Find the support you need to connect your water devices to the Pentair Home and Pentair Pro apps. Pentair has …Charlotte. May 13, 2018. #8. Te pump model is:: [h=1]Pentair SuperFlo VS Energy Efficient Variable Speed Pool Pump | 1.5HP Single Phase 115-230V 50-60HZ | 342001 [/h] This pump is supposed to have a 3yr. warranty, but Pentair apparently will not recognize online pump sales under their warranty. It was installed by a Pool Pro.Currently, I have the following issues: 1. EasyTouch will not operate the Intelliflo. Pump display shows "Display not active" indicating good comms. Pump work fine on schedule programmed at the unit itself. 2. EashTouch operates all other features, including the iChlor connected to the same J20. 3.Oct 25, 2017 · The IntelliFlo is controlled by a serial cable that gets plugged into the pump's control panel. When the cable is attached and the EasyTouch is in the Auto mode (Not Service mode) the pump's display will read "Display Not Active". If the pump's display does not say Display Not Active, then that is a pretty good indication that the communication ... Re: Anyone ever have the LCD screen go out on the Intelliflo My display went out the same way. The pump still worked, but the display was unreadable. Pentair replaced the display module as Jason noted without replacing the pump. Mine was replaced at the end of the season last year, and we are just opening now, so we will see how the long it lasts.

If you have any questions please contact us through our website at: https://www.poolspecialists.com/

The IntelliSync Pump Control and Monitoring System gives you smart device control of Pentair pumps such as IntelliFlo® and SuperFlo® Variable Speed Pumps. Through the convenience of the Pentair Home app, this pool pump controller* lets you adjust your pump, plus get monitoring alerts on select models. Affordable pool automation: a smart ...

Jan 5, 2023. #1. Our Pentair superflo SF-N1-1A is broken - it makes a jamming sound when trying to turn on and then shuts down due to overheating. It was installed in 2017 so I’m guessing it’s at the end of its 5-7 year lifespan (per google). Local pool shop recommended replacing this 1HP unit with a Pentair IntelliFlo i2.The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. It is being practiced by thousands of pool owners just like you. We are a registered 501(c)3 non-profit that is funded by user donations. Please consider Supporting TFP!2. IntelliCenter Features - The following are the major features of the Pentair IntelliCenter Control System as somewhat outlined in the Pentair documentation. 4” x 3” capacitive touch sensitive color screen at the control panel which also incorporates a manual and automatic day/night color screen mode.Pool (or Spa) 85*F. Air 81*F. Fri - 05:46 PM. If the above is ok, I would reload the protocol adapter and then download the PC program again. At this point I would only worry about getting ScreenLogic working via your PC. Once it works, than worry about the phone. Use this Pentair site... ScreenLogic Update.SWG Type. Hayward Turbo Cell (T-CELL-5) Sep 15, 2022. #18. For surge protection it is recommended to have one in each panel and where possible, one at the end device like a power bar for a computer or TV. Best you can do for pool equipment is add a Siemens Boltshield in all the panel (s). Takes 2 spaces.Apr 29, 2020 · About. Pentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy.com/que... 0:00 / 1:22 Pentair intelliflo pump: Display not active askthepoolguy 11.6K subscribers Subscribe Like Share Save 24K views 3 years ago #teamlegendary #legendaryescapes #askthepoolguy#1 Hello. I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however.Basically the pump can see the EasyTouch but the EasyTouch can't see the pump.. The RS-485 has different circuits.. It sends commands out on one circuit and receives commands on another circuit. We have seen several pump where the send circuit is dead, but the pump's screen still says "Display not active" because the receive circuit is still ...Nov 10, 2020 · If the communication with the intelliflo pump and Intellicenter is not working, that would be an issue (assuming your pool circuit is active and you are not in service mode). Report. Jimrahbe. Mod Squad. TFP Expert. LifeTime Supporter. Jul 7, 2014. 31,579. Bedford, TX.

The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for unparalleled efficiency. Potomac. Jun 14, 2018. #1. I replaced my old pump with the Pentair 342001 Superflo VS today. When I first powered it up, the screen came on no problem. I primed the pump, then turned it on for the first time. The pump started up, got almost to full running, then shut off. Now all it will do is blink the LEDs. I have turned off the breaker, then ...Jun 13, 2018 · Re: Intelliflo Pump has No Info on LED Screen. I have to wait on the circuit board waterproofer stuff before I do it. It is on order from Amazon. If I am pulling it out to work on it I want to do it right. IOW I am doing the weatherstripping and circuit board protection. I will turn the screen 180° as well because when my heater goes in I wont ... Instagram:https://instagram. redeem v bucks.comjazzy skye youtubespectrum outage map louisville kymatthew berry rankings week 4 13 years ago. reset VF to factory=. Press and hold 4 top buttons then release. Then hold down the two middle keys while holding down select and escape at the same time. At Application set up press select. To govern the pump to a 2HP or 1HP max, press the 4 top keys, arrow to PAR 699, change to 1 or 2 and power down, power up.Pentair Intellichlor Overview - IC15 IC20 IC30 IC40 IC60. In this video I give an overview of how most saltwater chlorinators work. Fix/replace your saltwate... wotlk classic prot paladin buildtamil doll Jun 5, 2011. #2. Make sure that the communication cable is connected and not cut anywhere. Check that the IntelliFlo local address matches with the address used in the IntelliTouch. Make sure that the IntelliFlo has been assigned a circuit name on the IntelliTouch. Report. J. mens ugg slippers koolaburra The Pentair Home app accepts a wide range of Pentair Connected water devices that can be used throughout a home to help your customers move, improve and enjoy their water. However, at this time, Pentair Home and Pentair Pro are not integrated with other smart home devices, or connected via voice with at home assistants like Alexa or Google Home.Down below, will be a series of alarms and warnings with the reason. Offline - The Pentair cloud cannot connect to your pump. This could be caused by a power outage at the pump or router, or a loss of WiFi signal to the pump. Priming failure- This can be caused by a lack of water in the volute strainer basket.Jun 30, 2019 · I have the ScreenLogic Config app on my iPhone. I went to the IntelliFlo Setup section and see Pump 1 and Pump 2 listed. Pump 1 is my main pump and Pump 2 is my cleaner pump. Both pumps are set to "none," which makes sense since neither was a IntelliFlo. Now that Pump 1 is an IntelliFlo, I know it's obvious that I should set it to VSF.